Skip to main content

Technical Specifications & Data Sheets

Technical Specifications & Data Sheets

Complete technical resource library for Solar Gard® window film products. Access product data sheets, NFRC certifications, ASTM test results, compliance documentation, and installation specifications.

Solar Control Window Films

TrueVue Dual-Reflective Films

Premium dual-reflective solar control with low interior reflectivity.

NFRC CertifiedASTM E2190
  • VLT Range: 15%–50%
  • SHGC: 0.22–0.45
  • UV Rejection: 99%
View Specs →

Ecolux Low-E Films

Four-season insulation with Low-E technology for year-round energy savings.

NFRC CertifiedLow-E
  • VLT Range: 50%–70%
  • Winter U-Factor Improvement: Up to 35%
  • UV Rejection: 99%
View Specs →

Silver HC Reflective Films

High-performance reflective films for maximum solar heat rejection.

NFRC CertifiedHigh Rejection
  • Total Solar Energy Rejected: Up to 79%
  • Glare Reduction: Up to 83%
  • UV Rejection: 99%
View Specs →

Safety & Security Window Films

Armorcoat 4-Mil Clear Safety Film

Basic safety film for fragment retention and accident protection.

ASTM C1036ANSI Z97.1
  • Thickness: 4 mil
  • Tensile Strength: 25,000 PSI
  • Break Strength: 125 lbs/in
View Specs →

Armorcoat 8-Mil Blast Mitigation Film

Blast mitigation film meeting GSA and DoD security requirements.

UFC 4-010-01GSA Tested
  • Thickness: 8 mil
  • Tensile Strength: 25,000 PSI
  • Break Strength: 250 lbs/in
View Specs →

Armorcoat 14-Mil Maximum Security Film

Maximum protection film for high-security federal and defense facilities.

UFC 4-010-01ISC Level
  • Thickness: 14 mil
  • Tensile Strength: 25,000 PSI
  • Break Strength: 500 lbs/in
View Specs →

Compliance & Certification Standards

StandardDescriptionApplicable Products
NFRCNational Fenestration Rating Council — Energy performance certificationSolar Control, Low-E Films
ASTM E2190Standard Specification for Insulating Glass Unit PerformanceAll Films
ASTM C1036Standard Specification for Flat GlassSafety Films
ANSI Z97.1Safety Performance Specifications for GlazingSafety & Security Films
UFC 4-010-01DoD Minimum Antiterrorism Standards for BuildingsArmorcoat 8-Mil, 14-Mil
GSA/ISCInteragency Security Committee Physical Security CriteriaArmorcoat Security Films
CPSC 16 CFR 1201Consumer Product Safety Commission Safety StandardAll Safety Films
GSA-TS01-2003GSA Standard Test Method for Glazing and Glazing SystemsBlast Mitigation Films

Energy Performance Data

Verified Energy Performance

Solar Gard window films have been tested and verified by independent laboratories for energy performance:

  • DOE/NREL Studies: Confirmed 25–40% reduction in solar heat gain
  • GSA Testing: 2–6 year payback period for Low-E films in federal buildings
  • LBNL Modeling: Measurable energy savings across all U.S. climate zones
  • ENERGY STAR Alignment: Products meet ENERGY STAR performance criteria

Installation Specifications

Solar Gard Professional Installation Standards

  • Surface Preparation: Glass must be clean, free of debris, and dry
  • Application Method: Wet application with manufacturer-approved solution
  • Edge Gap: 1/16" to 1/8" from frame edge (standard); edge-to-edge for security applications
  • Curing Time: 30–60 days depending on climate and film type
  • Temperature Requirements: Installation temperature between 40°F and 100°F
  • Warranty: Manufacturer warranty valid only with authorized installation

Warranty Information

Product CategoryCommercial WarrantyResidential Warranty
Solar Control Films10–15 YearsLifetime
Low-E Films (Ecolux)10 YearsLifetime
Safety Films (Armorcoat)10 YearsLifetime
Security Films (8-Mil, 14-Mil)10 YearsLifetime
Decorative Films5 Years10 Years
Anti-Graffiti (Graffitigard)5 YearsN/A

Request Technical Documentation

Need Specific Technical Data

Contact us for product data sheets, test reports, compliance certificates, and custom specification packages for your project.

Request Technical Package Email: pwf.estimates@gmail.com