Technical Specifications & Data Sheets
Complete technical resource library for Solar Gard® window film products. Access product data sheets, NFRC certifications, ASTM test results, compliance documentation, and installation specifications.
Solar Control Window Films
TrueVue Dual-Reflective Films
Premium dual-reflective solar control with low interior reflectivity.
NFRC CertifiedASTM E2190- VLT Range: 15%–50%
- SHGC: 0.22–0.45
- UV Rejection: 99%
Ecolux Low-E Films
Four-season insulation with Low-E technology for year-round energy savings.
NFRC CertifiedLow-E- VLT Range: 50%–70%
- Winter U-Factor Improvement: Up to 35%
- UV Rejection: 99%
Silver HC Reflective Films
High-performance reflective films for maximum solar heat rejection.
NFRC CertifiedHigh Rejection- Total Solar Energy Rejected: Up to 79%
- Glare Reduction: Up to 83%
- UV Rejection: 99%
Safety & Security Window Films
Armorcoat 4-Mil Clear Safety Film
Basic safety film for fragment retention and accident protection.
ASTM C1036ANSI Z97.1- Thickness: 4 mil
- Tensile Strength: 25,000 PSI
- Break Strength: 125 lbs/in
Armorcoat 8-Mil Blast Mitigation Film
Blast mitigation film meeting GSA and DoD security requirements.
UFC 4-010-01GSA Tested- Thickness: 8 mil
- Tensile Strength: 25,000 PSI
- Break Strength: 250 lbs/in
Armorcoat 14-Mil Maximum Security Film
Maximum protection film for high-security federal and defense facilities.
UFC 4-010-01ISC Level- Thickness: 14 mil
- Tensile Strength: 25,000 PSI
- Break Strength: 500 lbs/in
Compliance & Certification Standards
| Standard | Description | Applicable Products |
|---|---|---|
| NFRC | National Fenestration Rating Council — Energy performance certification | Solar Control, Low-E Films |
| ASTM E2190 | Standard Specification for Insulating Glass Unit Performance | All Films |
| ASTM C1036 | Standard Specification for Flat Glass | Safety Films |
| ANSI Z97.1 | Safety Performance Specifications for Glazing | Safety & Security Films |
| UFC 4-010-01 | DoD Minimum Antiterrorism Standards for Buildings | Armorcoat 8-Mil, 14-Mil |
| GSA/ISC | Interagency Security Committee Physical Security Criteria | Armorcoat Security Films |
| CPSC 16 CFR 1201 | Consumer Product Safety Commission Safety Standard | All Safety Films |
| GSA-TS01-2003 | GSA Standard Test Method for Glazing and Glazing Systems | Blast Mitigation Films |
Energy Performance Data
Verified Energy Performance
Solar Gard window films have been tested and verified by independent laboratories for energy performance:
- DOE/NREL Studies: Confirmed 25–40% reduction in solar heat gain
- GSA Testing: 2–6 year payback period for Low-E films in federal buildings
- LBNL Modeling: Measurable energy savings across all U.S. climate zones
- ENERGY STAR Alignment: Products meet ENERGY STAR performance criteria
Installation Specifications
Solar Gard Professional Installation Standards
- Surface Preparation: Glass must be clean, free of debris, and dry
- Application Method: Wet application with manufacturer-approved solution
- Edge Gap: 1/16" to 1/8" from frame edge (standard); edge-to-edge for security applications
- Curing Time: 30–60 days depending on climate and film type
- Temperature Requirements: Installation temperature between 40°F and 100°F
- Warranty: Manufacturer warranty valid only with authorized installation
Warranty Information
| Product Category | Commercial Warranty | Residential Warranty |
|---|---|---|
| Solar Control Films | 10–15 Years | Lifetime |
| Low-E Films (Ecolux) | 10 Years | Lifetime |
| Safety Films (Armorcoat) | 10 Years | Lifetime |
| Security Films (8-Mil, 14-Mil) | 10 Years | Lifetime |
| Decorative Films | 5 Years | 10 Years |
| Anti-Graffiti (Graffitigard) | 5 Years | N/A |
Request Technical Documentation
Need Specific Technical Data
Contact us for product data sheets, test reports, compliance certificates, and custom specification packages for your project.
Request Technical Package Email: pwf.estimates@gmail.com